Is a CGM useful if you do not have diabetes?
A CGM may show how your own meals and activity move your glucose, but no trial has shown it improves health in people without diabetes.
Continuous glucose monitors (CGMs) were built for people with diabetes, but in 2024 the FDA cleared an over-the-counter version for adults who do not use insulin, including people without diabetes who are curious about food and exercise1. They can show your own patterns. What they have not shown is that wearing one makes a healthy person healthier: benefit and harm in this group are not established, and reviews call the data scarce10,11.
What you can do
- Know what normal looks like: in 153 lean, healthy people, glucose stayed between 70 and 140 mg/dL for a median of 96% of the time3.
- Treat a single reading with caution: one 2026 reanalysis found day-to-day noise explains most 'personal' differences, though n-of-1 trials disagree6,7.
- If you try one, look at patterns over days rather than single peaks, since spike harm in people without diabetes is unproven8.
Be careful if
- The FDA says over-the-counter CGMs are not for people with problematic low blood sugar and are not designed to alert you to it1.
- Anyone with a history of disordered eating or food anxiety should talk to a clinician first; the effect of CGMs on these conditions has barely been studied10.
- Smartwatches and smart rings that claim to read glucose without a sensor are not FDA-authorized, and inaccurate readings can be dangerous2.
Go deeper
How it works What it does in your body, in plain words 4 min
What is on the market, and for whom
A CGM is a small sensor worn on the skin that records glucose through the day and night3. In March 2024 the FDA cleared the first over-the-counter system, the Dexcom Stelo, for anyone 18 or older who does not use insulin, a group the agency described as including people with diabetes managed with oral medicines and people without diabetes who want to understand how diet and exercise affect their blood sugar1.
The FDA attached limits. The system is not for people with problematic low blood sugar, it is not designed to alert the user to low blood sugar, and users should not make medical decisions from its output without talking to a health care provider1. Adverse events in the clinical study submitted to the agency included local infection, skin irritation, and pain or discomfort1.
A separate FDA safety communication from February 2024 warns against a different product class: smartwatches and smart rings that claim to estimate glucose without piercing the skin. The FDA said it has not authorized, cleared or approved any such device, and that inaccurate readings could lead people who take insulin or similar drugs to take the wrong dose2. That warning does not cover watch apps that display data from FDA-authorized sensors2.
What "normal" looks like
Healthy people's glucose is not flat. In a multicenter study of 153 healthy, non-obese people wearing a sensor for up to 10 days, average glucose was 98 to 99 mg/dL in every age group except those over 60, in whom it was 104 mg/dL3. The median time spent between 70 and 140 mg/dL was 96%, and a typical person spent about 30 minutes a day above 140 mg/dL and about 15 minutes a day below 70 mg/dL3. In other words, brief excursions above 140 or below 70 are part of normal life, not a sign of disease3.
Why two people react differently to the same meal
The main appeal of wearing a CGM is the finding that people respond differently to identical foods. In the PREDICT 1 study of 1,002 twins and unrelated adults in the United Kingdom, the variation between people after identical meals was large for glucose (a population coefficient of variation of 68%), and larger for blood triglycerides (103%)4. An earlier study of 800 people and 46,898 meals reached the same conclusion about glucose5.
But how much of that is a stable personal trait, and how much is day-to-day noise? A 2026 analysis argues that much of it is noise: when the same person repeats a glucose test, results differ enough to account for most of the apparent person-to-person differences between foods6. A series of n-of-1 trials found the opposite pattern, with large variation between people and high consistency within each person over time7. The question is open.
Are spikes harmful?
This is the claim that sells the devices, and it is the weakest link. A systematic review of 71 studies found that glucose variability is higher in people with prediabetes, but is not clearly linked to insulin sensitivity, fatty liver, body fat, blood lipids, blood pressure or oxidative stress; most of the studies were cross-sectional, so they cannot show that spikes cause anything8. A link to atherosclerosis and heart events was seen in people who already had coronary disease, and the authors called for prospective studies8.
Does wearing one change behavior?
Pooled trials suggest a modest effect on blood sugar, but nearly all were in people with diabetes9. In people without diabetes, a 2026 review found only 12 studies and concluded that large, durable benefits and stand-alone efficacy are not established10.
Accuracy, anxiety and eating habits
The FDA review found the Stelo performed similarly to other CGMs of its class1. How accurate any consumer sensor is in the normal, non-diabetic glucose range is a separate question that the studies above do not settle.
On the psychological side, the honest summary is that there is little data. The 2026 review found psychosocial evidence insufficient to establish benefit or exclude harm10. A small study of orthorexia (an unhealthy fixation on eating "correctly") in sensor users was done in people with type 1 diabetes12. For related context see orthorexia and wellness culture. For what normal blood tests show, see understanding your blood test results, and for the earliest stage of glucose trouble, prediabetes and insulin resistance. A related practice with its own evidence is a walk after meals. For people who do have diabetes, see CGMs in diabetes.
The evidence The studies, what they found, and how much to trust them 6 min · 12 sources
Reference ranges in healthy people
Shah and colleagues (2019) ran a multicenter prospective study at 12 centers. They enrolled non-pregnant, healthy, non-obese children and adults aged 6 and older; 153 participants aged 7 to 80 wore a blinded Dexcom G6 for up to 10 days with once-daily calibration3. Mean glucose was 98 to 99 mg/dL (5.4 to 5.5 mmol/L) in all age groups except those over 60, whose mean was 104 mg/dL (5.8 mmol/L)3. The median time in the 70 to 140 mg/dL range was 96% (interquartile range 93 to 98), median time above 140 mg/dL was 2.1% (30 minutes a day), and median time below 70 mg/dL was 1.1% (15 minutes a day)3. The mean within-person coefficient of variation was 17 ± 3%3. These are benchmark values for a lean, healthy group wearing one sensor model for 10 days; they do not describe people with obesity or older adults with other conditions3.
Between-person variability in meal responses
PREDICT 1 (Berry and colleagues, 2020) recruited 1,002 twins and unrelated healthy adults in the UK and measured responses in the clinic and at home4. After identical meals, the population coefficient of variation was 103% for triglycerides, 68% for glucose and 59% for insulin4. For triglycerides, person-specific factors such as the gut microbiome explained more of the variance (7.1%) than meal macronutrients (3.6%); for glucose the order was reversed, with 6.0% for person-specific factors and 15.4% for macronutrients, and genetic variants had a modest impact on predictions (9.5% for glucose)4. The findings were validated in a separate US cohort of 100 people4. A machine-learning model predicted glucose responses well (r = 0.77) and triglyceride responses less well (r = 0.47)4. The authors say the findings may inform personalized diets; the study did not test whether following such advice improves health4.
Zeevi and colleagues (2015) monitored 800 people for a week, measured responses to 46,898 meals, and found high variability in response to identical meals5. A prediction algorithm was validated in an independent 100-person cohort, and a blinded randomized dietary intervention based on the algorithm produced significantly lower postprandial glucose responses and consistent changes in gut microbiota5. That is a short-term change in a blood measure, not a change in disease or survival5.
The counter-argument: much of it may be noise
Della Corte and colleagues (2026) re-analyzed data from 382 healthy adults (1,022 glucose reference tests and 1,116 food tests across 9 carbohydrate-rich foods)6. If a person's response to a food is simply their own reference response scaled by the food's glycemic index, the prediction errors did not exceed the person's own test-retest variability (root mean square deviation 0.78 versus 1.02 mmol/L), with about 90% of predictions falling within each participant's own test-retest range6. Synthetic data with no person-specific effects reproduced the observed distributions, and the authors concluded that most between-person variation reflects day-to-day variability in glucose tolerance6. This is a secondary analysis under standardized conditions, not a direct test of real-life meals, and it is a single group's reading of the data6.
Zhang and colleagues (2025) ran a series of n-of-1 trials with standardized meals in 176 healthy Chinese adults7. They saw large variation in postprandial hyperglycemia between individuals but high consistency within individuals; their personalized glycemic sensitivity index was reproducible over a 2-year interval (intraclass correlation 0.73) and over 3 months in a second study of 30 people (0.88)7. Together,6 and7 show that the field disagrees about how stable personal food responses are.
Do glucose excursions predict disease in people without diabetes?
Hjort and colleagues (2024) systematically reviewed 71 studies that evaluated glycemic variability with CGM for 24 hours or more in people without diabetes; the majority were cross-sectional8. Variability was higher in prediabetes and inversely associated with beta cell function8. It was not clearly associated with insulin sensitivity, fatty liver disease, adiposity, blood lipids, blood pressure or oxidative stress8. In people with coronary disease it may be positively associated with the degree of atherosclerosis and with cardiovascular events8. The authors concluded that variability may be an important risk measure in people without diabetes but that prospective studies of incident disease are warranted8. A 2025 systematic review of CGM for cardiovascular prevention in people without diabetes made the same point more bluntly: data in this population are scarce and the effect on cardiovascular outcomes is unclear11. No trial in the references here tested whether reducing spikes prevents any disease8,11.
Does CGM feedback change behavior or outcomes?
Richardson and colleagues (2024) pooled 25 randomized trials with 2,996 participants in which CGM feedback was compared with no feedback9. Most trials were in adults with type 2 diabetes (17 of 25); 11 trials (44%) reported conflicts of interest with CGM makers9. CGM feedback reduced HbA1c by 0.28% (95% CI 0.15 to 0.42; heterogeneity I2 = 88%) and increased time in range by 7.4% (95% CI 2.0 to 12.8), with non-significant effects on time above range, BMI and weight9. Only 4 of 25 studies evaluated dietary change and 5 of 25 evaluated physical activity9. The authors called the effect favorable but modest9.
Makkena and colleagues (2026) reviewed 12 studies in adults without diabetes in which participants could see their glucose10. Two randomized dietary comparisons suggested selected improvements: in one 8-week trial of CGM plus low-glycemic-index education versus education alone, carbohydrate intake fell by 15.2 g more (95% CI -20.9 to -9.5), glycemic index by 10.0 (-13.1 to -6.9) and glycemic load by 19.9 (-29.0 to -10.7)10. Physical activity showed no clear difference (-28.5 MET-min/week; 95% CI -171.9 to 114.8)10. Certainty was low for dietary outcomes and very low for the rest10. The review's own wording is that CGM may support selected dietary changes as an adjunct within structured education, but stand-alone efficacy is not established10.
Mental health and eating behavior
Direct evidence is thin. Makkena found psychosocial evidence insufficient to establish benefit or exclude harm and device-burden evidence sparse10. Cosentino and colleagues (2023) compared 44 adults with type 1 diabetes who used flash or continuous monitors with matched colleagues and classmates without diabetes12. Orthorexia screening scores did not differ significantly on the ORTO-15 (scores under 40 in 72% versus 65%, p = 0.48), though the median score on a second instrument, the Dusseldorf Orthorexie Scale, was higher in patients; none of the metabolic measures correlated with the test scores12. This is a small cross-sectional study in a population that must monitor glucose for medical reasons, so it says little about healthy people who choose to wear a sensor12. The concern that CGMs could feed food anxiety is plausible, but the evidence in the references here neither confirms nor excludes it10,12.
How sure are we?
We rate the answer 2 (emerging). The reference ranges are well measured, and the large between-person differences in glucose after meals are replicated, but their meaning is disputed3,4,6,7. There is no trial showing that spike-avoidance, or CGM use, improves health outcomes in people without diabetes, and the few trials in this group are small and of low certainty8,10,11. Much of the behavior-change evidence comes from people with diabetes and from studies where industry ties were common9.
More on Continuous Glucose Monitors
Sources
- FDA Clears First Over-the-Counter Continuous Glucose Monitor. U.S. Food and Drug Administration. FDA Press Announcement, 2024. Source (opens in a new tab)
- Do Not Use Smartwatches or Smart Rings to Measure Blood Glucose Levels: FDA Safety Communication. U.S. Food and Drug Administration. FDA Safety Communication, 2024. Source (opens in a new tab)
- Continuous Glucose Monitoring Profiles in Healthy Nondiabetic Participants: A Multicenter Prospective Study. Shah VN, DuBose SN, Li Z, Beck RW, Peters AL, Weinstock RS, Kruger D, Tansey M, Sparling D, Woerner S, Vendrame F, Bergenstal R, Tamborlane WV, Watson SE, Sherr J. The Journal of Clinical Endocrinology and Metabolism, 2019. PubMed 31127824 (opens in a new tab)
- Human postprandial responses to food and potential for precision nutrition. Berry SE, Valdes AM, Drew DA, Asnicar F, Mazidi M, Wolf J, Capdevila J, Hadjigeorgiou G, Davies R, Al Khatib H, Bonnett C, Ganesh S, Bakker E, Hart D, Mangino M, Merino J, Linenberg I, Wyatt P, Ordovas JM, Gardner CD, Delahanty LM, Chan AT, Segata N, Franks PW, Spector TD. Nature Medicine, 2020. PubMed 32528151 (opens in a new tab)
- Personalized Nutrition by Prediction of Glycemic Responses. Zeevi D, Korem T, Zmora N, Israeli D, Rothschild D, Weinberger A, Ben-Yacov O, Lador D, Avnit-Sagi T, Lotan-Pompan M, Suez J, Mahdi JA, Matot E, Malka G, Kosower N, Rein M, Zilberman-Schapira G, Dohnalová L, Pevsner-Fischer M, Bikovsky R, Halpern Z, Elinav E, Segal E. Cell, 2015. PubMed 26590418 (opens in a new tab)
- Individual glycemic responses scale predictably with the glycemic index: evidence against person-specific food effects. Della Corte KA, Brand-Miller J, Wolever TM, Della Corte D. The American Journal of Clinical Nutrition, 2026. PubMed 42177949 (opens in a new tab)
- Quantification of personalized glycemic sensitivity to food and its potential for precision nutrition in a series of n-of-1 trials. Zhang K, Fu Y, Gou W, Miao Z, Tian Y, Liang Y, Liang X, Shuai M, Xiao C, Wang J, Xu F, Jiang Z, Gao C, Ma S, Ordovas JM, Zheng JS. The American Journal of Clinical Nutrition, 2025. PubMed 40754388 (opens in a new tab)
- Glycemic variability assessed using continuous glucose monitoring in individuals without diabetes and associations with cardiometabolic risk markers: A systematic review and meta-analysis. Hjort A, Iggman D, Rosqvist F. Clinical Nutrition, 2024. PubMed 38401227 (opens in a new tab)
- The efficacy of using continuous glucose monitoring as a behaviour change tool in populations with and without diabetes: a systematic review and meta-analysis of randomised controlled trials. Richardson KM, Jospe MR, Bohlen LC, Crawshaw J, Saleh AA, Schembre SM. International Journal of Behavioral Nutrition and Physical Activity, 2024. PubMed 39716288 (opens in a new tab)
- Behavioral and Psychosocial Effects of Participant-Visible Continuous Glucose Monitoring in Adults Without Diabetes: A Systematic Review. Makkena HB, Nimmagadda Y, Boinapelly N, George A, Daruvuri N, Sunar RR, Guda S. Medicina, 2026. PubMed 42796420 (opens in a new tab)
- Non-Invasive Continuous Glucose Monitoring in Patients Without Diabetes: Use in Cardiovascular Prevention-A Systematic Review. Wilczek F, van der Stouwe JG, Petrasch G, Niederseer D. Sensors, 2025. PubMed 39796978 (opens in a new tab)
- Orthorexia nervosa and type 1 diabetes: results of a cross-sectional study. Cosentino C, Rossi E, Pala L, Lelmi R, Campanino C, Ricca V, Mannucci E, Dicembrini I, Rotella F. Acta Diabetologica, 2023. PubMed 36806923 (opens in a new tab)