How much do CGMs help people with diabetes?
CGM probably lowers HbA1c in adults with diabetes, including those not on insulin, but trials lasted only months and some were funded by Dexcom.
For people with diabetes who use insulin, randomized trials of continuous glucose monitors (CGMs) show lower HbA1c and more time in the target glucose range1,3,4. A 2026 trial extends that to type 2 diabetes managed without insulin5. The gains are real but moderate, and they were measured over months, not years1,3,5.
What you can do
- Judge a CGM by time in range, not single readings: the 2019 consensus target for most adults with diabetes is over 70% of time between 70 and 180 mg/dL8,10.
- Ask your diabetes team how often to review the data; participants in the DIAMOND type 2 trial wore the sensor about 6.7 days a week2.
- Expect modest gains in type 2 diabetes: HbA1c fell 0.3 to 0.4 percentage points more with CGM in the insulin-treated type 2 trials2,3.
Be careful if
- Trials ran 3 to 8 months, so long-term effects on complications are not known1,3.
- Two of the main trials were funded by Dexcom, and 44% of the trials in one meta-analysis reported ties to CGM makers2,5,7.
- Insulin dosing decisions belong with a diabetes team; the FDA's over-the-counter clearance covers only adults who do not use insulin9.
Go deeper
How it works What it does in your body, in plain words 2 min
What a CGM adds to a finger-stick meter
A traditional meter gives a glucose number at the moment of the test. A CGM records glucose continuously, so people can see trends and time spent high or low rather than a handful of snapshots3. Trials compared CGM against ordinary blood glucose meter monitoring or usual care, in people who were all receiving diabetes care1,2,3,5.
Time in range
CGM data are summarized as "time in range", the share of readings between 70 and 180 mg/dL, along with time below 70 and time above 1808. An international panel of clinicians, researchers and people with diabetes met in 2019 to agree on how CGM data should be reported and what targets to work toward, and stressed that targets must be personalized10. Their table of targets for most adults with type 1 or type 2 diabetes was more than 70% of time in range, less than 4% of time below 70 mg/dL and less than 1% below 54 mg/dL; for older or high-risk people it was more than 50% in range and less than 1% below 70 mg/dL10. Those figures are in the paper's full text, not its abstract8,10.
Who has been studied
- Type 1 diabetes on injections: the DIAMOND trial1.
- Type 2 diabetes on several daily insulin injections: the DIAMOND type 2 trial2.
- Type 2 diabetes on basal (once- or twice-daily) insulin only: the MOBILE trial3,4.
- Type 2 diabetes not on insulin: the CONNECT trial, published in 20265.
- Type 1 diabetes on pumps and automated systems: the iDCL closed-loop trial6.
From CGM to automated insulin delivery
Closed-loop systems, sometimes called an "artificial pancreas", connect a CGM to an insulin pump and a control algorithm that adjusts insulin automatically6. One 6-month trial compared such a system with a sensor-augmented pump6.
Over-the-counter sensors
The FDA's 2024 clearance of an over-the-counter CGM covers adults who do not use insulin, including people with diabetes managed with oral medicines9. The agency said the system is not designed to alert users to low blood sugar and that medical decisions should involve a provider9. For people without diabetes see CGMs for people without diabetes; for the condition itself see type 2 diabetes and prediabetes.
The evidence The studies, what they found, and how much to trust them 5 min · 10 sources
Type 1 diabetes on injections: DIAMOND
The DIAMOND trial (Beck and colleagues, 2017) randomized 158 adults with type 1 diabetes who used multiple daily insulin injections and had HbA1c of 7.5% to 9.9% at 24 US endocrinology practices; 105 were assigned to CGM and 53 to usual care, and 98% completed the study1. HbA1c fell by 1.0% at 24 weeks in the CGM group and 0.4% in controls, an adjusted difference of -0.6% (95% CI -0.8% to -0.3%; P < .001)1. Median time below 70 mg/dL was 43 minutes a day with CGM and 80 minutes a day with usual care (P = .002), and severe hypoglycemia occurred in 2 participants in each group1. In the CGM group, 93% used the sensor 6 or more days a week in month 61. The authors noted that longer-term effectiveness and clinical outcomes needed further study1.
Type 2 diabetes on multiple daily injections: DIAMOND type 2
In 158 adults with type 2 diabetes receiving multiple daily insulin injections (CGM n = 79, usual care n = 79; HbA1c 7.5% to 9.9%), HbA1c fell to 7.7% in the CGM group and 8.0% in controls at 24 weeks, an adjusted difference of -0.3% (95% CI -0.5% to 0.0%; P = 0.022)2. The groups did not differ meaningfully in CGM-measured hypoglycemia or quality of life2. The CGM group averaged 6.7 days of use a week2. The trial's limitation was its 6-month follow-up, and its primary funding source was Dexcom2.
Type 2 diabetes on basal insulin: MOBILE
MOBILE (Martens and colleagues, 2021) randomized 175 adults with type 2 diabetes treated with basal insulin and no mealtime insulin at 15 US centers, 116 to CGM and 59 to a blood glucose meter3. Mean baseline HbA1c was 9.1%; at 8 months it was 8.0% with CGM and 8.4% with a meter, an adjusted difference of -0.4% (95% CI -0.8% to -0.1%; P = .02)3. Time in the 70 to 180 mg/dL range was 59% with CGM versus 43% (difference 15%; 95% CI 8% to 23%), and time above 250 mg/dL was 11% versus 27%3. Severe hypoglycemia occurred in 1 participant in each group3. A 2025 analysis of the first 3 months reported an adjusted HbA1c difference of -0.6% (95% CI -0.9% to -0.3%), a 9.3% gain in time in range, and a lower weekly hypoglycemic event rate with CGM, with improvement visible within the first 7 days of use4. The 3-month figure is larger than the 8-month figure, a reminder that the effect may fade or that analyses differ by time point3,4.
Type 2 diabetes not on insulin: CONNECT
The CONNECT trial, published in 2026, randomized 283 adults with type 2 diabetes who were not using insulin (145 to CGM, 138 to routine care) at 22 US primary care practices for 26 weeks5. HbA1c fell from 8.8% to 7.2% with CGM and from 8.7% to 8.0% with routine care, an adjusted difference of -0.9 percentage points (95% CI -1.1 to -0.6; P < 0.001)5. Time in range was 21 percentage points higher with CGM, time below 70 mg/dL was 0.20 percentage points lower, and no severe hypoglycemia was reported5. The trial was funded by Dexcom, and it is a single trial5. A separate meta-analysis of 25 trials with 2,996 participants, mostly in type 2 diabetes, found that CGM feedback lowered HbA1c by 0.28% (95% CI 0.15 to 0.42) and raised time in range by 7.4%, with 11 of 25 trials (44%) reporting ties to CGM makers7. Heterogeneity across those trials was high (I2 = 88%)7.
Automated insulin delivery
In the iDCL trial (Brown and colleagues, 2019), 168 people aged 14 to 71 with type 1 diabetes were randomized 2:1 to a closed-loop system (112) or a sensor-augmented pump (56) for 6 months6. Time in the 70 to 180 mg/dL range rose from 61% to 71% with closed loop and stayed at 59% with the control pump, an adjusted difference of 11 percentage points (95% CI 9 to 14; P < 0.001)6. Time below 70 mg/dL was 0.88 percentage points lower and HbA1c 0.33 percentage points lower with closed loop6. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group6. The system ran in closed-loop mode a median of 90% of the time6.
Time-in-range targets and guidelines
The 2019 international consensus on time in range is a recommendations paper rather than a trial, so its targets reflect expert agreement, and the numbers quoted above come from its full text (Table 3)8,10. The consensus panel also said the targets must be personalized10.
How sure are we?
We rate the answer 4 (strong). Multiple randomized trials in different insulin-treated groups agree on a lower HbA1c and more time in range, and the newest trial extends the finding to people not on insulin1,2,3,5. Weaknesses are short follow-up (3 to 8 months across the trials3,4), no trial of long-term complications, a benefit that is modest in some groups (about 0.3 percentage points in DIAMOND type 2), and industry funding or ties in the trials and pooled studies2,5,7. The largest drop, 0.9 points, came from the one trial in people not using insulin, so the benefit is not confined to insulin users5.
More on Continuous Glucose Monitors
Sources
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial. Beck RW, Riddlesworth T, Ruedy K, Ahmann A, Bergenstal R, Haller S, Kollman C, Kruger D, McGill JB, Polonsky W, Toschi E, Wolpert H, Price D, DIAMOND Study Group. JAMA, 2017. PubMed 28118453 (opens in a new tab)
- Continuous Glucose Monitoring Versus Usual Care in Patients With Type 2 Diabetes Receiving Multiple Daily Insulin Injections: A Randomized Trial. Beck RW, Riddlesworth TD, Ruedy K, Ahmann A, Haller S, Kruger D, McGill JB, Polonsky W, Price D, Aronoff S, Aronson R, Toschi E, Kollman C, Bergenstal R, DIAMOND Study Group. Annals of Internal Medicine, 2017. PubMed 28828487 (opens in a new tab)
- Effect of Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin: A Randomized Clinical Trial. Martens T, Beck RW, Bailey R, Ruedy KJ, Calhoun P, Peters AL, Pop-Busui R, Philis-Tsimikas A, Bao S, Umpierrez G, Davis G, Kruger D, Bhargava A, Young L, McGill JB, Aleppo G, Nguyen QT, Orozco I, Biggs W, Lucas KJ, Polonsky WH, Buse JB, Price D, Bergenstal RM, MOBILE Study Group. JAMA, 2021. PubMed 34077499 (opens in a new tab)
- Rapid improvements in glycemic management with use of continuous glucose monitoring in adults with type 2 diabetes treated with basal insulin: 3-month analysis of the MOBILE study. Martens TW, Beck RW, Griffen C, Di J, Elkind-Hirsch K, Johnson ML, Castle JR, Beck SE, Bergenstal RM. BMJ Open Diabetes Research & Care, 2025. PubMed 41192933 (opens in a new tab)
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes. Oser TK, Martens T, Ruedy KJ, Bergford S, Calhoun P, Chang KL, Kramer ES, Klug BA, Anderson RL, Cook BR, Pickering D, Ortega M, Peterson B, Davidson L, Schmid R, Desai ND, Burkett E, Haynes JL, Herman A, Topiwala SM, Bailey R, Oser SM, Cadet NN, Johnson ML, Elkind-Hirsch KE, Beck SE, Castle JR, Beck RW, CONNECT Study Group. New England Journal of Medicine, 2026. PubMed 42878622 (opens in a new tab)
- Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes. Brown SA, Kovatchev BP, Raghinaru D, Lum JW, Buckingham BA, Kudva YC, Laffel LM, Levy CJ, Pinsker JE, Wadwa RP, Dassau E, Doyle FJ, Anderson SM, Church MM, Dadlani V, Ekhlaspour L, Forlenza GP, Isganaitis E, Lam DW, Kollman C, Beck RW, iDCL Trial Research Group. New England Journal of Medicine, 2019. PubMed 31618560 (opens in a new tab)
- The efficacy of using continuous glucose monitoring as a behaviour change tool in populations with and without diabetes: a systematic review and meta-analysis of randomised controlled trials. Richardson KM, Jospe MR, Bohlen LC, Crawshaw J, Saleh AA, Schembre SM. International Journal of Behavioral Nutrition and Physical Activity, 2024. PubMed 39716288 (opens in a new tab)
- Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range. Battelino T, Danne T, Bergenstal RM, Amiel SA, Beck R, Biester T, Bosi E, Buckingham BA, Cefalu WT, Close KL, Cobelli C, Dassau E, DeVries JH, Donaghue KC, Dovc K, Doyle FJ, Garg S, Grunberger G, Heller S, Heinemann L, Hirsch IB, Hovorka R, Jia W, Kordonouri O, Kovatchev B, Kowalski A, Laffel L, Levine B, Mayorov A, Mathieu C, Murphy HR, Nimri R, Nørgaard K, Parkin CG, Renard E, Rodbard D, Saboo B, Schatz D, Stoner K, Urakami T, Weinzimer SA, Phillip M. Diabetes Care, 2019. PubMed 31177185 (opens in a new tab)
- FDA Clears First Over-the-Counter Continuous Glucose Monitor. U.S. Food and Drug Administration. FDA Press Announcement, 2024. Source (opens in a new tab)
- Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (full text, Table 3). Battelino T, Danne T, Bergenstal RM, et al. (international consensus panel). Diabetes Care, 2019. Source (opens in a new tab)